本平台为互联网非涉密平台,严禁处理、传输国家秘密或工作秘密

基于低场核磁共振技术的烟草含水率检测方法

Quantifying tobacco moisture content based on low-field nuclear magnetic resonance

  • 摘要: 为准确、快速检测烟草加工过程中物料含水率,建立了基于低场核磁共振技术的烟草含水率测定方法,并与烘箱法含水率检测结果进行了对比,结果表明:①低场核磁共振法检测烟草含水率时,CPMG序列与FID序列相比较优,样品量7 g、扫描次数16次时测量结果较好。②所建立的基于低场核磁共振技术的烟草样品含水率检测方法具有较好的精密度和准确性,日内精密度和日间精密度结果的变异系数均小于2%。③与烘箱法相比,低场核磁共振法检测结果具有较好的稳定性和准确性,且检测时间(2 min)远低于烘箱法(150 min),适用于烟草含水率的快速、准确检测。

     

    Abstract: In order to accurately determine the moisture content in tobacco during processing, a rapid method based on the CPMG signals of low-field nuclear magnetic resonance (LF-NMR) was established. The results were compared with those determined by the conventional oven moisture method. The results showed that:1) With the LF-NMR method, CPMG sequences were better than FID sequences, and the optimized sample volume and scanning numbers were 7 g and 16 respectively. 2) The established LF-NMR method featured good precision and high accuracy with the variation coefficients of intra- and inter-day precision less than 2%. 3) The LF-NMR method was more stable and accurate than the oven method, in addition the test time (2 min) was much shorter than that (150 min) of the oven method. The established method is suitable for the rapid and accurate determination of moisture content in tobacco.

     

/