本平台为互联网非涉密平台,严禁处理、传输国家秘密或工作秘密

烟草中硫酸根离子测定方法的改进

An Improved Method for Determining Sulfate Anion in Tobacco

  • 摘要: 为快速准确地测定烟草中硫酸根离子的含量,对样品的前处理和测定过程进行了改进:①采用180℃(30min)→280℃(30min)→380℃(30min)→520℃(30min)阶段升温法灰化样品,升温速率8℃/min,从而防止了样品因突然剧烈升温爆溅带来的实验误差;②采用在弱酸性介质中与铬酸钡反应,用分光光度法在420nm处测定生成的铬酸根离子,再由此计算烟草样品中硫酸根离子的含量。方法的回收率在94%~102%,RSD为1.35%~1.49%,检测限为1.51×10-4。测定结果与硫酸钡法相比,没有显著性差异。

     

    Abstract: For fast and accurately determining sulfate anion in tobacco, some improvements were made in sample preparation and measuring procedure:1) tobacco samples were ashed in a muffle furnace according to the programmed steps:180℃ (initial, retaining for 30min) →280℃ (30min) →380℃ (30min) →520℃ (end, 30min), increasing at rate 8℃/min, in order to avoid the experimental error due to splashes caused by sudden temperature increase;and 2) the sulfate anion in tobacco sample solution was reacted with barium chromate in weak acidic medium, the produced chromate anion was determined by UV-spectrometer at 420nm and the content of sulfate anion in tobacco was calculated with its absorption.The recovery of sulfate anion varied from 94% to 102%, its RSD was from 1.35% to 1.49%, and detection limit was 1.51×10-4.There was no significant difference between the results obtained by this method and by a conventional weighting method, barium sulfate method.

     

/

返回文章
返回