透气度流量盘测量结果的修正
Correction of Measurements of Air Permeability Standards
-
摘要: 为验证ISO 2965-2009中透气度流量盘测量结果修正公式的准确性,在可调节大气压实验舱中,分别选择22℃,24℃两个温度点,及86,93,99,101,106 kPa 5个大气压力点的不同环境条件对18个流量盘进行了流量值测量实验。结果表明:①线性流量盘的测量结果不需修正,可直接用作流量值;②非线性流量盘测量结果修正到标准条件后,将修正结果作为非线性流量盘的流量值。并通过线性流量盘和非线性流量盘在结果修正后和未修正两种情况下对卷烟纸透气度测量结果的影响实验,验证了以上实验结论的正确性。Abstract: To verify the accuracy of correction formula for the measurements of air permeability standards in ISO 2965-2009,18 air permeability standards were tested in an atmospheric pressure chamber at 22,24℃ and 86,93,99,101,106 kPa,respectively.The results showed that:1) The measurement values of linear standards could be used directly without correction.2) The measurement values of non-linear standards should be corrected to the standard conditions.The mentioned results were verified by the experiments of the effects of linear standards and non-linear standards on the measurements of air permeability of cigarette paper before and after correction.