  • 摘要: 建立了顶空气相色谱-质谱联用测定烟草中磷化氢残留的方法。样品在顶空进样器40℃下恒温振荡进样,经气相色谱Elite-624毛细管柱(60 m×320μm×1.8μm)分离,质谱检测器SIR模式下监测质荷比为34的离子碎片测定。结果表明:①在0.25~5.00μg/L范围内方法线性良好,检出限0.0019μg/g,平均回收率90.29%,相对标准偏差4.54%(n=6)。②采用该方法测定烟草中的磷化氢残留,简便,安全,准确。

     

    Abstract: A headspace gas chromatography-mass spectrometry method was developed for determining phosphine residue in tobacco. The sample was injected after being oscillated at 40℃ in headspace sampler, then separated on GC Elite-624 capillary column (60 m×320 m×1.8 m), and finally determined by mass spectrometry monitoring ion fragment (m/z=34) under SIR mode. The results showed that:1) Good linearity was achieved when the content of PH3 ranged from 0.25-5.00 g/L. The detection limit, average recovery and relative standard deviation (RSD) (n=6) were 0.0019μg/g, 90.29% and 4.54%, respectively. 2) This method was simple, safe and accurate for determining phosphine residue in tobacco.

     

/