ZOU YING, LI QING-CHENG, LIAO XIAO-LING, LIU YONG-QIONG. Analysis of Selenium in Tobacco with Atomic Fluorescence SpectrometryJ. Tobacco Science & Technology, 2006, 39(8): 29-32. DOI: 10.3969/j.issn.1002-0861.2006.08.007
Citation: ZOU YING, LI QING-CHENG, LIAO XIAO-LING, LIU YONG-QIONG. Analysis of Selenium in Tobacco with Atomic Fluorescence SpectrometryJ. Tobacco Science & Technology, 2006, 39(8): 29-32. DOI: 10.3969/j.issn.1002-0861.2006.08.007

Analysis of Selenium in Tobacco with Atomic Fluorescence Spectrometry

  • A method for determination of microelement selenium in tobacco with hydride generation-atomic fluorescence spectrometry (HG-AFS) was developed, tobacco sample was digested by HNO3-HClO4(v/v: 4/1), then the resultant digestion solution was determined with HG-AFS.The recovery of selenium was 92.5%-97.5%with RSD < 6.0% in the linear range of 0-250μg/L, the detection limit of this method was 0.18μg/L.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint