MA XIANG, WEN YA-DONG, WANG YI, XIE LI-HUA, ZHANG JING. Application of On-Line FT-NIR Spectrometer in Primary Processing LineJ. Tobacco Science & Technology, 2007, 40(3): 16-18. DOI: 10.3969/j.issn.1002-0861.2007.03.003
Citation: MA XIANG, WEN YA-DONG, WANG YI, XIE LI-HUA, ZHANG JING. Application of On-Line FT-NIR Spectrometer in Primary Processing LineJ. Tobacco Science & Technology, 2007, 40(3): 16-18. DOI: 10.3969/j.issn.1002-0861.2007.03.003

Application of On-Line FT-NIR Spectrometer in Primary Processing Line

  • The prediction models of moisture content, total alkaloid, total sugar and total nitrogen in cut tobacco during primary processing were established with its spectra acquired by on-line FT-NIR spectrometer. The mean relative errors between predictive values and determined values of moisture content, total alkaloid, total sugar and total nitrogen were 1.1%, 1.9%, 2.1%, and 1.7%, respectively. It indicated that on-line monitoring of the chemical components in cut tobacco during primary processing with on-line FT-NIR spectrometer was feasible.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return