LI BIN, HU QI-XIU, LIU ZE, FENG QIAN, LIU GANG-YI, CHEN LIANG-YUAN. Non-destructive Detection of Strips Density Variation in Case by X-ray AttenuationJ. Tobacco Science & Technology, 2009, 42(7): 5-8,22. DOI: 10.3969/j.issn.1002-0861.2009.07.001
Citation: LI BIN, HU QI-XIU, LIU ZE, FENG QIAN, LIU GANG-YI, CHEN LIANG-YUAN. Non-destructive Detection of Strips Density Variation in Case by X-ray AttenuationJ. Tobacco Science & Technology, 2009, 42(7): 5-8,22. DOI: 10.3969/j.issn.1002-0861.2009.07.001

Non-destructive Detection of Strips Density Variation in Case by X-ray Attenuation

  • A method for determining density variation ratio(DVR) of strips in a case was established basing on X-ray attenuation, and the accuracy(correctness and precision) of the method was investigated.The results showed that:1) the fluctuation of X-ray intensity and strips density indications of the device was less than 1% in 24hours, which meets the requirements of strips density test;2) the precision range of strips density(Sρ, r) determined by X-ray was from 0.012 kg/m3 to 0.301 kg/m3, and its relationship with strips density was ln(Sρ, r)=-6.31+2.15ln(ρ);3) the absolute value of relative error was less than 5% when strips density in the case was over 200 kg/m3, and it would decrease with the increase of strips density;the precision of DVR(SDVR, r) was 0.0141%-0.0719% and independent of DVR;4) comparing with the method of sampling from 9 points, the density determined by X-ray device was higher, and the value of DVR was lower and more accurate.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return